184 / 2023-10-20 16:50:39
Study on the Loss Characteristics of Dry-Type Power Transformers Considering Stray Losses
Finite element method,Stray loss,Structural components,Transformer
终稿
Cheng Yang / Anhui Jixi Pumped Storage Energy Co., Ltd.
Hao Hu / Anhui Jixi Pumped Storage Energy Co., Ltd.
Peng Tian / Anhui Jixi Pumped Storage Energy Co., Ltd.
Jingwei Shi / Anhui Jixi Pumped Storage Energy Co., Ltd.
Zhenya Wang / Anhui Jixi Pumped Storage Energy Co., Ltd.
Chengbing Zhang / Beijing Zhongke Chuangshi Technology Development Co., Ltd.
This paper explores dry-type power transformer losses, focusing on stray losses. Using 3D frequency-domain nonlinear electromagnetic finite element analysis, these losses are investigated, particularly concerning load conditions and structural components. A method to measure stray losses is proposed by comparing simulation and experimental results. Findings reveal that stray losses during no-load tests are minimally impacted by structural components, but under short-circuit conditions, stray losses closely match rated conditions. It is suggested that stray losses induced by structural components are influenced by the current. Further analysis indicates that stray losses are directly proportional to current squared. Furthermore, simulation results are compared with factory test reports, which suggest that stray losses from structural components contribute to short-circuit losses. Valuable insights into power transformer loss characteristics are provided by this research, contributing to performance enhancement and efficiency improvement.
重要日期
  • 会议日期

    12月08日

    2023

    12月10日

    2023

  • 11月01日 2023

    初稿截稿日期

  • 12月10日 2023

    注册截止日期

主办单位
IEEE IAS
承办单位
Southwest Jiaotong University (SWJTU)
移动端
在手机上打开
小程序
打开微信小程序
客服
扫码或点此咨询