Purpose/Aim
In the urban distribution network, cross-linked polyethylene (XLPE) power cables are widely used because of their many advantages, and their insulation state affects the safe and reliable operation of the system. In the cable from the operation of the power grid to the scrap has a certain service life, different service length of the cable will be in different aging states, so it is particularly important to study the propagation characteristics of the partial discharge signal under different aging degrees. In order to obtain accurate partial discharge signal propagation characteristics, it is important to establish a refined cable model.
Experimental/Modeling methods
In order to obtain a refined model of XLPE power cable, the cable structure is first analyzed according to the physical object, and the equivalent impedance, capacitance and inductance are calculated with the help of comsol simulation software. Secondly, the degree of aging of the cable has a certain correspondence with its frequency domain dielectric parameters, so different cable frequency domain dielectric parameters can be set to approximate the partial discharge propagation characteristics of the cable under different aging degrees.
Results/discussion
According to the simulation results, the partial discharge signal shows different propagation characteristics in cables with different aging degrees, and the attenuation of the signal amplitude gradually increases with the increase of the static dielectric constant. Therefore, it can be known that as the degree of cable aging increases, the attenuation of the partial discharge signal in the cable is greater.
Conclusions
The propagation characteristics of the partial discharge signal in the cable under different aging conditions are not the same. Therefore, when conducting partial discharge tests on cables, it is necessary to consider the service time of the cables, so that the measured values obtained are closer to the actual discharge.
 
关键词
aging,XLPE cable,partial discharge,propagation characteristics
报告人
Shuyue Ma
Xi’an University of Technology

稿件作者
Hui Li Xi’an University of Technology
Shuyue Ma Xi’an University of Technology
Qian Wang Xi’an University of Technology
Qiming Xu Xi’an University of Technology
Rui Liu Xi’an University of Technology
Yifei Ma Xi’an University of Technology
Sichen Qin Xi’an University of Technology
发表评论
验证码 看不清楚,更换一张
全部评论
重要日期
  • 会议日期

    09月25日

    2022

    09月29日

    2022

  • 08月15日 2022

    提前注册日期

  • 09月10日 2022

    报告提交截止日期

  • 11月10日 2022

    注册截止日期

  • 11月30日 2022

    初稿截稿日期

  • 11月30日 2022

    终稿截稿日期

主办单位
IEEE DEIS
承办单位
Chongqing University
移动端
在手机上打开
小程序
打开微信小程序
客服
扫码或点此咨询