32 / 2021-10-03 14:43:57
A low voltage ride through measure suitable for doubly-fed wind power generators
DFIG; Crowbar protection; DC-Chopper circuit; Symmetrical short circuit fault; Asymmetric short circuit fault;
全文录用
Shuyu Liu / Xi'an Polytechnic University
Grid-connected wind power generators in wind farms require low voltage ride-through functions to meet grid failures, especially uninterrupted operation under grid voltage sag failures. Therefore, aiming at the shortcomings of conventional Crowbar, this article designs a protection scheme based on the combination of Crowbar and DC-Chopper. A wind farm simulation model was established, and the short-circuit current output characteristics of a wind turbine with low voltage ride through capability (LVRT) under asymmetric fault and symmetric fault conditions were simulated. And verified its optimized performance.
重要日期
  • 会议日期

    07月11日

    2023

    08月18日

    2023

  • 11月10日 2021

    初稿截稿日期

  • 12月10日 2021

    注册截止日期

  • 12月11日 2021

    报告提交截止日期

主办单位
IEEE IAS
承办单位
IEEE IAS Student Chapter of Southwest Jiaotong University (SWJTU)
IEEE IAS Student Chapter of Huazhong University of Science and Technology (HUST)
IEEE PELS (Power Electronics Society) Student Chapter of HUST
移动端
在手机上打开
小程序
打开微信小程序
客服
扫码或点此咨询